Power Supply

 

 

Overvoltage Protection

 

 

Power Consumption

 

 

In this unit, there is only one power supply pin (X1.23).

The ground pin (X1.22) is the recommended pin for the power supply return line. The following table shows the power supply pin locations.

 

Power supply pins

Designation

Connector / pin number

Potential

Supply voltage (for logic and power)

X1.23

+12/+24 VDC (8,4…36 VDC)

Ground (for supply voltage)

X1.22

GND

Data ground (for CAN, RS-232)

X1.9
X1.10

GND

AI ground

X1.18

GND

(max current is 100 mA)

I/O ground

X1.19

GND

Supply outputs

Reference supply (for external devices)

X1.16

 

+5 VDC / max 100 mA

 

 

Always use an external fuse to protect the unit. The fuse is needed for reverse voltage and overload protection. For more information, see section Power Supply Cabling.

 

Electrical characteristics

Symbol

Parameter

Conditions

Min

Max

Units

VI

Nominal Input Voltage

 

8,4

36

V

VI-Load-dump

Max Input Transient Voltage Level

(Note 1)

 

123

V

VI-max

Max Continuous Input Voltage Level

(Note 2)

-20

70

V

VI-ovp

Overvoltage Threshold Level

 

typ. 37

V

VI-uvp

Undervoltage Threshold Level

 

typ. 8

V

Supply voltage monitoring

VI-range

Nominal Input Voltage measuring range

 

0

36

V

Note 1: Load dump protection according to ISO7636-2: 2004 pulse 5, Us=+123 V 

Note 2: Limited functionality when the voltage is higher than the nominal. If the voltage is less than 7,7 V, the unit is in non-operational state.